batterystorageforbusiness

kW vs kWh: how to read the size of a commercial battery

Two numbers describe a battery and they answer different questions. Get them confused and you can buy a battery that holds plenty and cannot deliver it fast enough, or the other way round.

kW vs kWh comes down to this: kW is power, how fast a battery can deliver energy right now. kWh is energy, how much it can deliver in total. A commercial battery is specified by both, and the ratio between them is its duration: 250 kWh at 125 kW is a two-hour system. This page explains the difference, the related terms on a datasheet, and how a business turns its own load into a size. Our buying guide to commercial battery storage shows where the size decision fits in the whole purchase.

FREE FEASIBILITY

What size would your site need?

Send the postcode and rough annual spend. The free feasibility summary reads your consumption and suggests a size.

Within 3 working days: a 2-page summary with your indicative system size, installed cost band, the value streams that apply to your site and an honest payback range. If storage does not stack up, it says so.

No lead auction and no marketing list. Published by SEO Dons, an independent information site: not an installer, supplier or manufacturer.

Power and energy in one picture

Think of a water tank. The tank's volume is the energy, kWh. The width of the tap is the power, kW. A large tank with a narrow tap holds a lot but empties slowly. A small tank with a wide tap empties fast. In the same way, 1 kWh is the energy delivered by 1 kW sustained for one hour, so a 100 kW discharge for 30 minutes delivers 50 kWh. Both numbers belong to the battery, and the inverter limits the kW however much the cells could hold.

Duration: dividing one by the other

Duration in hours is energy divided by power. Keeping the power at 100 kW, three different batteries look like this:

Type Power Energy Duration C-rate
One-hour system 100 kW 100 kWh 1 h 1C
Two-hour system 100 kW 200 kWh 2 h 0.5C
Four-hour system 100 kW 400 kWh 4 h 0.25C

The C-rate is the same information expressed relative to capacity: 1C empties the battery in an hour, 0.5C in two, 0.25C in four. It is the reciprocal of the duration in hours.

Which number does your site need?

Work from what the battery is for.

None of these can be sized from an annual total. They need the shape of your demand, which is why a year of half-hourly data comes first. How to read half-hourly data before buying a battery shows what to look for.

Nominal capacity, usable capacity and depth of discharge

Datasheets usually list the battery's nominal energy, the total the cells could hold. The usable energy is lower, because the battery management system keeps the cells from being fully emptied or fully charged. The share you can use is related to the depth of discharge, how far down the battery is allowed to go. Two batteries with the same nominal kWh can therefore deliver different usable kWh, and quotes that state only the nominal figure flatter the price per kWh. Ask for usable energy, and ask whether it is measured at the battery or at the AC output after the inverter.

Round-trip efficiency: what comes back

Charging and discharging both lose some energy as heat and in the inverter. Round-trip efficiency is the share you get back. The US National Renewable Energy Laboratory's 2024 Annual Technology Baseline uses 85% for commercial batteries, so 100 kWh going in returns about 85 kWh. That is a planning assumption rather than a guarantee, and a supplier's claim should state what it is measured on. The loss matters for any strategy that buys cheap energy and uses it later, because the price gap has to cover the missing 15%.

MW and MWh

The same logic applies at larger scales: 1 MW is 1,000 kW and 1 MWh is 1,000 kWh. A one-megawatt battery holding two megawatt-hours is a two-hour system, just as 100 kW with 200 kWh is. Containerised commercial systems are usually quoted in MWh.

How the two numbers move the price

NREL's cost model for commercial storage splits the price into a part that scales with the energy in the pack, a part that scales with the power of the inverter and balance-of-system equipment, and a fixed part. That is why more kW for the same kWh costs more, and why bigger systems cost less per kWh. Our guide to commercial battery storage cost sets out the published UK bands, and how to compare commercial battery quotes shows how to put quotes on the same basis. If you want the equipment itself explained, start with what a BESS is.

A datasheet checklist

  1. Nominal energy (kWh) and usable energy (kWh), and where each is measured.
  2. Continuous power (kW) at the AC output, and how long it can be held.
  3. Peak power for short bursts, and for how many seconds.
  4. Round-trip efficiency, with the conditions.
  5. Duration at continuous power, which should equal usable kWh divided by kW.
  6. Temperature limits and any derating of power in hot or cold conditions.
  7. Warranty: years, energy throughput or cycle count, and guaranteed remaining capacity.

kW vs kWh: common questions

What is the difference between kW and kWh in a battery?

kW measures power, how fast the battery can charge or discharge at any moment. kWh measures energy, how much the battery can hold or deliver in total. A battery with a large kWh figure and a small kW figure holds a lot but releases it slowly, and the reverse holds a little and releases it fast.

What does a two-hour battery mean?

It means the battery can discharge at its full rated power for two hours, so its energy in kWh is twice its power in kW. A 125 kW battery holding 250 kWh is a two-hour system. The same idea gives one-hour and four-hour systems, and it is the duration that matters when you are shaving a peak that lasts a set number of hours.

How many kWh does my business need?

Multiply the power you want to remove or back up by the hours you need it, then add allowance for the share of capacity that is not usable and for losses. To cut a peak by 100 kW for three hours you need at least 300 kWh of usable energy at the AC output. The real answer comes from your half-hourly data, which shows how high and how long your peaks are.

What is a C-rate?

The C-rate is the rate of charge or discharge relative to the battery’s capacity. 1C empties the battery in one hour, 0.5C in two hours, 0.25C in four hours and 2C in 30 minutes. It is the reciprocal of the duration in hours, so a two-hour battery runs at 0.5C.

Is 100 kWh a lot?

It depends on the site. In published UK cost bands, 100 kWh is described as a mainstream commercial size, and the same source treats systems up to 50 kWh as small and containerised systems from 500 kWh as large. Whether it is enough depends on your peak and how long it lasts.

Sources

FREE FEASIBILITY

Get a size for your site

Send the postcode and rough annual spend. The free feasibility summary reads your consumption and shows a sensible power and energy rating, within 3 working days.

What you get, within 3 working days: a 2-page battery feasibility summary naming your indicative system size (kW and kWh), the installed cost band, which value streams actually apply to your site (peak-shaving, red-band DUoS avoidance, load shifting, solar self-consumption, grid services), and an honest payback range. If storage does not stack up for your site, the summary says so.

What we will not do
  • We do not run a lead auction. Your details are never sold or passed to a panel of installers.
  • No marketing list, no newsletter sign-up, no unsolicited calls.
  • We will not oversize a system to inflate a quote, or model a payback we cannot defend.

Published by SEO Dons, a specialist commercial energy information network. We are independent: we are not an energy supplier and not a battery manufacturer.

We reply within one working day. Prefer to talk first? +44 7707 970661

Independent guidance for UK commercial sites

  • Independent & supplier-neutral
  • No manufacturer tie-ins
  • UK commercial & industrial sites